Subsystem/actuators
This subsystem only needs be explicitly specified for rotorcrafts where there are several different actuators implementations and you have to add the correct one depending on the ESCs you use.
Currently possible actuators subsystems are
- mkk
- asctec
- asctec_v2
- pwm_supervision
- skiron
- heli
MKK
Mikrokopter ESCs
File: conf/airframes/myplane.xml |
<firmware name="rotorcraft"> ... <subsystem name="actuators" type="mkk"> <configure name="MKK_I2C_SCL_TIME" value="50"/> <!-- this is optional, 150 is default, use 50 for 8 motors--> </subsystem> <define name="I2C_TRANSACTION_QUEUE_LEN" value="10"/> <!-- default is 8, increase to 10 or more for 8 motors--> </firmware> |
- MKK_I2C_SCL_TIME is specific to LPC21x based boards (e.g. booz) and not necessary for STM32 based boards (e.g. Lisa/M/L)
XML configuration
required defines in section ACTUATORS_MKK:
- NB: number of motors
- ADDR: the I2C addresses of your motors
File: conf/airframes/myplane.xml |
<section name="ACTUATORS_MKK" prefix="ACTUATORS_MKK_"> <define name="NB" value="4"/> <define name="ADDR" value="{ 0x52, 0x54, 0x56, 0x58 }"/> </section> |
You also need the matching Supervision section.
Asctec v1
These controllers already to the mixing themselves, so the Supervision section is not needed.
File: conf/airframes/myplane.xml |
<firmware name="rotorcraft"> ... <subsystem name="actuators" type="asctec"/> </firmware> |
Asctec v2
File: conf/airframes/myplane.xml |
<firmware name="rotorcraft"> ... <subsystem name="actuators" type="asctec_v2"/> </firmware> |
XML configuration
You need the matching Supervision section.
PWM Supervision
Only for stm32 based autopilot boards (eg. Lisa/M, Lisa/L)
File: conf/airframes/myplane.xml |
<firmware name="rotorcraft"> ... <subsystem name="actuators" type="pwm_supervison"> <define name="SERVO_HZ" value="400"/> </subsystem> </firmware> |
The define SERVO_HZ sets a higher update frequency for the pwm controllers which is needed for good response times.
XML configuration
File: conf/airframes/myplane.xml |
<servos min="0" neutral="0" max="0xff"> <servo name="FRONT" no="0" min="1000" neutral="1000" max="2000"/> <servo name="BACK" no="1" min="1000" neutral="1000" max="2000"/> <servo name="LEFT" no="2" min="1000" neutral="1000" max="2000"/> <servo name="RIGHT" no="3" min="1000" neutral="1000" max="2000"/> </servos> |
You also need the matching Supervision section and define the SUPERVISION_STOP_MOTOR to the pwm value you need to send to your controllers for stopping the motors.