Real Time Plotter

The plotter (in sw/logalizer/) is a facility to plot real time data broadcasted on the Paparazzi network bus. Main features:

  • Drag&Drop from the messages window of any field
  • Multi-curves, constant curves
  • Configurable update delay and memory size
  • Basic scaling mechanism

First Try

Launch a simulation with a messages window (for example the Versatile Sim session provided as an example). Note that the messages can be simply launched with

sw/ground_segment/tmtc/messages -c telemetry:* -c ground

from a shell. Launch the plotter with (or configure it in your session)

sw/logalizer/plotter

From the messages window, select the field pos_x in the NAVIGATION message and drop it on the Plotter. Do the same with pos_y, you should get something similar to

Plotter pos_x pos_y

Delete the pos_y curve by selecting it in the Curves menu and drop the desired_x from the DESIRED message:

Plotter pos_x pos_y

It is also possible to draw curves with different scales in the same window. Delete both curves and Reset (or open a new plotter from the File menu) and drop desired_altitude from the DESIRED message. Enter 0.01 (to convert cm into m) in the Scale entry box and drop alt from GPS message on the Scale label. Change the desired altitude from the GCS (+30m) to observe the behaviour of the altitude controller:

Plotter pos_x pos_y

Pause

The display update can be Suspended while the data are still stored: no disctoninuity on a Restart. The data update can also be Stoped while the display is active (e.g. resizable). These features are available from the File menu or via keyboard accelerators.

More Tuning

A constant curve can be added by entering a float value in the Constant box.

The update time can be set with the slider; it should be smaller than the period of the faster data you want to plot.