Difference between revisions of "Lisa/MXS v1.0"

From PaparazziUAV
Jump to navigation Jump to search
(link to pdf on hardware github)
Line 7: Line 7:
In the default mode, only 4 UART, 1 SPI, 1 I2C, 3 ADC and 6 servos are available. But since the F4 has massive alternate functions, more options are possible.
In the default mode, only 4 UART, 1 SPI, 1 I2C, 3 ADC and 6 servos are available. But since the F4 has massive alternate functions, more options are possible.


  - if you need 8 PWM, then I2C can become servo 7 and 8
  - if you need 8 PWM outputs, then I2C1 can become output for servo 7 and 8
  - if you need 5 UART servo 1 and 2 can become UART6
  - if you need 5 UART's, servo 1 and 2 can become UART6 TX/RX
  - if you need more ADC then servo 5 and 6 can become ADC
  - if you need more ADC's then servo 5 and 6 can become ADC's
- if you need to use a tiny RC receiver with PPM output, then servo 6 can become the PPM input
  - if you need hardware flow control, UART2 RTS and CTS are on servo 5 and 6
  - if you need hardware flow control, UART2 RTS and CTS are on servo 5 and 6
  - if you need more than 8 servos, then nearly every UART and SPI can become extra PWM (except SPI-SS)
  - if you need more than 8 servos, then nearly every UART and SPI can become extra PWM (except SPI-SS)

Revision as of 14:38, 17 November 2022

Lisa/Mx-Small is a smaller version of Lisa/M with an STM32F4 processor for only 1.45 gram. See Lisa-Mx for more information. See Github Paparazzi - Hardware Lisa MXS for schematics.

Lisa mx s v1 0.png

In the default mode, only 4 UART, 1 SPI, 1 I2C, 3 ADC and 6 servos are available. But since the F4 has massive alternate functions, more options are possible.

- if you need 8 PWM outputs, then I2C1 can become output for servo 7 and 8
- if you need 5 UART's, servo 1 and 2 can become UART6 TX/RX
- if you need more ADC's then servo 5 and 6 can become ADC's
- if you need to use a tiny RC receiver with PPM output, then servo 6 can become the PPM input
- if you need hardware flow control, UART2 RTS and CTS are on servo 5 and 6
- if you need more than 8 servos, then nearly every UART and SPI can become extra PWM (except SPI-SS)