	<entry>
		<id>http://wiki.paparazziuav.org/w/index.php?title=Module/Honeywell_HIH-4030&amp;diff=14510&amp;oldid=prev</id>
		<title>Martinmm: Created page with &quot;__NOTOC__ Honeywell HIH-4030 ===Overview===  The Honeywell HIH-4030 is a simple relative humidity sensor. It outputs an analog voltage and needs…&quot;</title>
		<link rel="alternate" type="text/html" href="http://wiki.paparazziuav.org/w/index.php?title=Module/Honeywell_HIH-4030&amp;diff=14510&amp;oldid=prev"/>
		<updated>2013-03-07T23:03:15Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot;__NOTOC__ &lt;a href=&quot;/wiki/File:Hih4030.jpg&quot; title=&quot;File:Hih4030.jpg&quot;&gt;thumb|right|Honeywell HIH-4030&lt;/a&gt; ===Overview===  The Honeywell HIH-4030 is a simple relative humidity sensor. It outputs an analog voltage and needs…&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;__NOTOC__&lt;br /&gt;
[[Image:Hih4030.jpg|thumb|right|Honeywell HIH-4030]]&lt;br /&gt;
===Overview===&lt;br /&gt;
&lt;br /&gt;
The Honeywell HIH-4030 is a simple relative humidity sensor. It outputs an analog voltage and needs an additional temperature sensor for compensation. The sensor was flown only once for testing...&lt;br /&gt;
&lt;br /&gt;
{|border=&amp;quot;1&amp;quot;&lt;br /&gt;
|-valign=&amp;quot;top&amp;quot;&lt;br /&gt;
||Module name||meteo/humid_hih&lt;br /&gt;
|-&lt;br /&gt;
|Sensor type&lt;br /&gt;
|humidity&lt;br /&gt;
|-&lt;br /&gt;
|Range&lt;br /&gt;
| 0 .. 100 %RH&lt;br /&gt;
|-&lt;br /&gt;
&lt;br /&gt;
|Resolution&lt;br /&gt;
|? %RH&lt;br /&gt;
|-&lt;br /&gt;
|Refresh rate&lt;br /&gt;
|4Hz&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
[http://www.sparkfun.com/datasheets/Sensors/Weather/SEN-09569-HIH-4030-datasheet.pdf Product data sheet]&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
===Hardware===&lt;br /&gt;
Supply the sensor with 5V and connect the output with an ADC input through a 68kOhm/36kOhm resistor bridge. Standard pin is ADC_3 (AD0.6) on ADC1/J10 for the Tiny/TWOG. We used the temperature sensor part of the SHT75 for compensation.&lt;br /&gt;
&lt;br /&gt;
Supplier:&lt;br /&gt;
&lt;br /&gt;
[http://www.sparkfun.com/products/9569 Sparkfun]&lt;br /&gt;
&lt;br /&gt;
==== Wiring ====&lt;br /&gt;
{|border=&amp;quot;1&amp;quot;&lt;br /&gt;
|-valign=&amp;quot;top&amp;quot;&lt;br /&gt;
||'''Tiny/TWOG ADC1 pin'''||'''Tiny/TWOG ADC1'''||'''HIH-4030'''&lt;br /&gt;
|-&lt;br /&gt;
|1&lt;br /&gt;
|GND&lt;br /&gt;
|GND&lt;br /&gt;
|-&lt;br /&gt;
|2&lt;br /&gt;
| +5V&lt;br /&gt;
|5V&lt;br /&gt;
|-&lt;br /&gt;
|3&lt;br /&gt;
|&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|4&lt;br /&gt;
|&lt;br /&gt;
|&lt;br /&gt;
|-&lt;br /&gt;
|5&lt;br /&gt;
|ADC3 (P0.30)&lt;br /&gt;
|OUT (through resistor bridge)&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
===Usage===&lt;br /&gt;
&lt;br /&gt;
To use the humidity sensor add:&lt;br /&gt;
{{Box Code|conf/airframes/myplane.xml|&lt;br /&gt;
&amp;lt;source lang=&amp;quot;xml&amp;quot;&amp;gt;&lt;br /&gt;
  &amp;lt;modules&amp;gt;&lt;br /&gt;
    &amp;lt;load name=&amp;quot;humid_hih.xml&amp;quot;/&amp;gt;&lt;br /&gt;
  &amp;lt;/modules&amp;gt;&lt;br /&gt;
&amp;lt;/source&amp;gt;&lt;br /&gt;
}}&lt;br /&gt;
&lt;br /&gt;
The ADC pins can be configured through defines, e.g.:&lt;br /&gt;
{{Box Code|conf/airframes/myplane.xml|&lt;br /&gt;
&amp;lt;source lang=&amp;quot;xml&amp;quot;&amp;gt;&lt;br /&gt;
  &amp;lt;modules&amp;gt;&lt;br /&gt;
    &amp;lt;load name=&amp;quot;humid_hih.xml&amp;quot;&amp;gt;&lt;br /&gt;
      &amp;lt;define name=&amp;quot;ADC_CHANNEL_HUMID_HIH&amp;quot; value=&amp;quot;ADC_4&amp;quot;/&amp;gt;&lt;br /&gt;
    &amp;lt;/load&amp;gt;&lt;br /&gt;
  &amp;lt;/modules&amp;gt;&lt;br /&gt;
&amp;lt;/source&amp;gt;&lt;br /&gt;
}}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
===Result message===&lt;br /&gt;
&lt;br /&gt;
The raw data (humid) and the converted result (fhumid/ftemp) is written to the log file. The message is automatically sent when new data is received, it does not have to be added to the telemetry file.&lt;br /&gt;
{{Box Code|conf/messages.xml|&lt;br /&gt;
&amp;lt;source lang=&amp;quot;xml&amp;quot;&amp;gt;&lt;br /&gt;
  &amp;lt;message name=&amp;quot;HIH_STATUS&amp;quot; id=&amp;quot;96&amp;quot;&amp;gt;&lt;br /&gt;
    &amp;lt;field name=&amp;quot;humid&amp;quot; type=&amp;quot;uint16&amp;quot;/&amp;gt;&lt;br /&gt;
    &amp;lt;field name=&amp;quot;fhumid&amp;quot; type=&amp;quot;float&amp;quot; unit=&amp;quot;rel_hum&amp;quot; format=&amp;quot;%.2f&amp;quot;/&amp;gt;&lt;br /&gt;
    &amp;lt;field name=&amp;quot;ftemp&amp;quot; type=&amp;quot;float&amp;quot; unit=&amp;quot;deg_celsius&amp;quot; format=&amp;quot;%.2f&amp;quot;/&amp;gt;&lt;br /&gt;
  &amp;lt;/message&amp;gt;&lt;br /&gt;
&amp;lt;/source&amp;gt;&lt;br /&gt;
}}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
Sample log file lines&lt;br /&gt;
 (none)&lt;br /&gt;
&lt;br /&gt;